{"title":"Distribution \u0026 Protection","description":null,"products":[{"product_id":"victron-smart-batteryprotect-12-24v-65a","title":"Battery Protect | Victron | Smart BatteryProtect 12\/24V-65A","description":"\u003cp\u003eThe Victron Smart BatteryProtect 12\/24V-65A is an automatic low-voltage disconnect (LVD) device that protects your 12V or 24V battery from deep discharge. Rated at 65A continuous, it connects in series between the battery and your DC loads — fridges, lights, pumps, entertainment systems — automatically cutting power when battery voltage drops to a programmable threshold. When the battery recovers through solar charging or alternator input, loads reconnect automatically. Built-in Bluetooth Smart adds wireless configuration and monitoring via the VictronConnect app. A must-have for caravans, 4WDs, and marine applications where battery protection matters.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eBuilt-in Bluetooth — configure and monitor via VictronConnect app (iOS \u0026amp; Android)\u003c\/li\u003e\n  \u003cli\u003eAutomatic low-voltage disconnect — protects battery from over-discharge\u003c\/li\u003e\n  \u003cli\u003eProgrammable disconnect and reconnect voltages\u003c\/li\u003e\n  \u003cli\u003e65A continuous rated \/ 250A peak (30s surge protection)\u003c\/li\u003e\n  \u003cli\u003eAlarm output with 12-second pre-disconnect warning\u003c\/li\u003e\n  \u003cli\u003eRemote on\/off input for system integration\u003c\/li\u003e\n  \u003cli\u003e90-second delayed disconnect prevents nuisance trips on short voltage dips\u003c\/li\u003e\n  \u003cli\u003eSolid-state MOSFET switching — no relays, ignition-proof, silent operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax Continuous Current\u003c\/td\u003e\n\u003ctd\u003e65A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak Current (30s)\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSystem Voltage\u003c\/td\u003e\n\u003ctd\u003e12\/24V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e6-35V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDisconnect Voltage Range\u003c\/td\u003e\n\u003ctd\u003eProgrammable 10–13V (12V) \/ 20–26V (24V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReconnect Voltage Range\u003c\/td\u003e\n\u003ctd\u003eProgrammable 11–14V (12V) \/ 22–28V (24V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSelf-consumption\u003c\/td\u003e\n\u003ctd\u003e1.4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBluetooth\u003c\/td\u003e\n\u003ctd\u003eBuilt-in Bluetooth\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eIP Rating (Electronics)\u003c\/td\u003e\n\u003ctd\u003eIP67 (fully potted)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e48 x 55 x 106 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eHow It Works\u003c\/h3\u003e\n\u003cp\u003eThe BatteryProtect installs in series between the battery and your DC loads — important: it protects loads only, never in the charge circuit or starter motor line. When battery voltage falls to the set disconnect threshold, the alarm output activates for 12 seconds as a warning before loads are cut after a 90-second delay. This delay prevents false trips from short-duration voltage sags under heavy starting loads. Once the charger (solar, alternator, or mains) raises the battery voltage back above the reconnect threshold, loads are automatically restored after a 30-second delay. MOSFET solid-state switching means no audible relay click, no arcing, and the unit is ignition-proof — suitable for fuel-present environments.\u003c\/p\u003e\n\n\u003ch3\u003eUse Cases\u003c\/h3\u003e\n\u003cp\u003eIn caravans and camper trailers, the BatteryProtect is most commonly used to protect the house battery from being flattened by the fridge, lighting, or 12V accessories while parked off-grid. At 65A rating, it handles the combined load of a compressor fridge, LED lighting, a water pump, and 12V entertainment with headroom to spare. When camp solar brings the battery back up overnight, everything reconnects automatically.\u003c\/p\u003e\n\u003cp\u003eFor 4WD touring and marine applications, the BatteryProtect is installed on the auxiliary battery to ensure that running loads — ARB fridges, winch power circuits, pumps — cannot flatten the battery to the point of a no-start. The 65A rating suits most dual-battery setups, and the IP67 electronics withstand the damp, vibration, and temperature extremes of these environments.\u003c\/p\u003e\n\n\u003ch3\u003eApp Control — VictronConnect\u003c\/h3\u003e\n\u003cp\u003eThe BatteryProtect Smart includes built-in Bluetooth Low Energy (BLE) for configuration and monitoring via the VictronConnect app (free, iOS and Android). Adjust disconnect and reconnect voltage thresholds, enable or disable the alarm output, view real-time battery voltage and unit status — all wirelessly from your phone. The Instant Readout feature lets you check live data without needing to pair the device. Bluetooth can also be disabled permanently for permanently installed systems where wireless access is not required.\u003c\/p\u003e\n\u003ch3\u003eWhy Buy From Revolution Power\u003c\/h3\u003e\n\u003cp\u003eRevolution Power is a Queensland-based Victron Energy specialist supplying caravanners, boaties, and off-grid installers across Australia. We stock the full BatteryProtect range from our Coomera, QLD warehouse and ship fast Australia-wide. Not sure which rating you need? The amp rating of your BatteryProtect must exceed the total combined current draw of all connected loads. Our team is happy to help with sizing — contact us before ordering if you're unsure.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":44799210127414,"sku":"BPR065022000","price":77.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/2989\/7782\/files\/Smart_20BatteryProtect_2012-24V_2065A_20_28front-angle_29.webp?v=1770622996"},{"product_id":"victron-smart-batteryprotect-12-24v-100a","title":"Battery Protect | Victron | Smart BatteryProtect 12\/24V-100A","description":"\u003cp\u003eThe Victron Smart BatteryProtect 12\/24V-100A is an automatic low-voltage disconnect (LVD) device that protects your 12V or 24V battery from deep discharge. Rated at 100A continuous, it connects in series between the battery and your DC loads — fridges, lights, pumps, entertainment systems — automatically cutting power when battery voltage drops to a programmable threshold. When the battery recovers through solar charging or alternator input, loads reconnect automatically. Built-in Bluetooth Smart adds wireless configuration and monitoring via the VictronConnect app. A must-have for caravans, 4WDs, and marine applications where battery protection matters.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eBuilt-in Bluetooth — configure and monitor via VictronConnect app (iOS \u0026amp; Android)\u003c\/li\u003e\n  \u003cli\u003eAutomatic low-voltage disconnect — protects battery from over-discharge\u003c\/li\u003e\n  \u003cli\u003eProgrammable disconnect and reconnect voltages\u003c\/li\u003e\n  \u003cli\u003e100A continuous rated \/ 600A peak (30s surge protection)\u003c\/li\u003e\n  \u003cli\u003eAlarm output with 12-second pre-disconnect warning\u003c\/li\u003e\n  \u003cli\u003eRemote on\/off input for system integration\u003c\/li\u003e\n  \u003cli\u003e90-second delayed disconnect prevents nuisance trips on short voltage dips\u003c\/li\u003e\n  \u003cli\u003eSolid-state MOSFET switching — no relays, ignition-proof, silent operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax Continuous Current\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak Current (30s)\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSystem Voltage\u003c\/td\u003e\n\u003ctd\u003e12\/24V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e6-35V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDisconnect Voltage Range\u003c\/td\u003e\n\u003ctd\u003eProgrammable 10–13V (12V) \/ 20–26V (24V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReconnect Voltage Range\u003c\/td\u003e\n\u003ctd\u003eProgrammable 11–14V (12V) \/ 22–28V (24V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSelf-consumption\u003c\/td\u003e\n\u003ctd\u003e1.4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBluetooth\u003c\/td\u003e\n\u003ctd\u003eBuilt-in Bluetooth\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eIP Rating (Electronics)\u003c\/td\u003e\n\u003ctd\u003eIP67 (fully potted)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e61 x 41 x 164 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eHow It Works\u003c\/h3\u003e\n\u003cp\u003eThe BatteryProtect installs in series between the battery and your DC loads — important: it protects loads only, never in the charge circuit or starter motor line. When battery voltage falls to the set disconnect threshold, the alarm output activates for 12 seconds as a warning before loads are cut after a 90-second delay. This delay prevents false trips from short-duration voltage sags under heavy starting loads. Once the charger (solar, alternator, or mains) raises the battery voltage back above the reconnect threshold, loads are automatically restored after a 30-second delay. MOSFET solid-state switching means no audible relay click, no arcing, and the unit is ignition-proof — suitable for fuel-present environments.\u003c\/p\u003e\n\n\u003ch3\u003eUse Cases\u003c\/h3\u003e\n\u003cp\u003eIn caravans and camper trailers, the BatteryProtect is most commonly used to protect the house battery from being flattened by the fridge, lighting, or 12V accessories while parked off-grid. At 100A rating, it handles the combined load of a compressor fridge, LED lighting, a water pump, and 12V entertainment with headroom to spare. When camp solar brings the battery back up overnight, everything reconnects automatically.\u003c\/p\u003e\n\u003cp\u003eFor 4WD touring and marine applications, the BatteryProtect is installed on the auxiliary battery to ensure that running loads — ARB fridges, winch power circuits, pumps — cannot flatten the battery to the point of a no-start. The 100A rating suits most dual-battery setups, and the IP67 electronics withstand the damp, vibration, and temperature extremes of these environments.\u003c\/p\u003e\n\n\u003ch3\u003eApp Control — VictronConnect\u003c\/h3\u003e\n\u003cp\u003eThe BatteryProtect Smart includes built-in Bluetooth Low Energy (BLE) for configuration and monitoring via the VictronConnect app (free, iOS and Android). Adjust disconnect and reconnect voltage thresholds, enable or disable the alarm output, view real-time battery voltage and unit status — all wirelessly from your phone. The Instant Readout feature lets you check live data without needing to pair the device. Bluetooth can also be disabled permanently for permanently installed systems where wireless access is not required.\u003c\/p\u003e\n\u003ch3\u003eWhy Buy From Revolution Power\u003c\/h3\u003e\n\u003cp\u003eRevolution Power is a Queensland-based Victron Energy specialist supplying caravanners, boaties, and off-grid installers across Australia. We stock the full BatteryProtect range from our Coomera, QLD warehouse and ship fast Australia-wide. Not sure which rating you need? The amp rating of your BatteryProtect must exceed the total combined current draw of all connected loads. Our team is happy to help with sizing — contact us before ordering if you're unsure.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":44799213338678,"sku":"BPR110022000","price":101.7,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/2989\/7782\/files\/Smart_20BatteryProtect_2012-24V_20100A_20_28front-angle_29.webp?v=1770623881"},{"product_id":"victron-smart-batteryprotect-12-24v-220a","title":"Battery Protect | Victron | Smart BatteryProtect 12\/24V-220A","description":"\u003cp\u003eThe Victron Smart BatteryProtect 12\/24V-220A is an automatic low-voltage disconnect (LVD) device that protects your 12V or 24V battery from deep discharge. Rated at 220A continuous, it connects in series between the battery and your DC loads — fridges, lights, pumps, entertainment systems — automatically cutting power when battery voltage drops to a programmable threshold. When the battery recovers through solar charging or alternator input, loads reconnect automatically. Built-in Bluetooth Smart adds wireless configuration and monitoring via the VictronConnect app. A must-have for caravans, 4WDs, and marine applications where battery protection matters.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eBuilt-in Bluetooth — configure and monitor via VictronConnect app (iOS \u0026amp; Android)\u003c\/li\u003e\n  \u003cli\u003eAutomatic low-voltage disconnect — protects battery from over-discharge\u003c\/li\u003e\n  \u003cli\u003eProgrammable disconnect and reconnect voltages\u003c\/li\u003e\n  \u003cli\u003e220A continuous rated \/ 600A peak (30s surge protection)\u003c\/li\u003e\n  \u003cli\u003eAlarm output with 12-second pre-disconnect warning\u003c\/li\u003e\n  \u003cli\u003eRemote on\/off input for system integration\u003c\/li\u003e\n  \u003cli\u003e90-second delayed disconnect prevents nuisance trips on short voltage dips\u003c\/li\u003e\n  \u003cli\u003eSolid-state MOSFET switching — no relays, ignition-proof, silent operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax Continuous Current\u003c\/td\u003e\n\u003ctd\u003e220A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak Current (30s)\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSystem Voltage\u003c\/td\u003e\n\u003ctd\u003e12\/24V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e6-35V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDisconnect Voltage Range\u003c\/td\u003e\n\u003ctd\u003eProgrammable 10–13V (12V) \/ 20–26V (24V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReconnect Voltage Range\u003c\/td\u003e\n\u003ctd\u003eProgrammable 11–14V (12V) \/ 22–28V (24V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSelf-consumption\u003c\/td\u003e\n\u003ctd\u003e1.4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBluetooth\u003c\/td\u003e\n\u003ctd\u003eBuilt-in Bluetooth\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eIP Rating (Electronics)\u003c\/td\u003e\n\u003ctd\u003eIP67 (fully potted)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e60 x 123 x 121 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eHow It Works\u003c\/h3\u003e\n\u003cp\u003eThe BatteryProtect installs in series between the battery and your DC loads — important: it protects loads only, never in the charge circuit or starter motor line. When battery voltage falls to the set disconnect threshold, the alarm output activates for 12 seconds as a warning before loads are cut after a 90-second delay. This delay prevents false trips from short-duration voltage sags under heavy starting loads. Once the charger (solar, alternator, or mains) raises the battery voltage back above the reconnect threshold, loads are automatically restored after a 30-second delay. MOSFET solid-state switching means no audible relay click, no arcing, and the unit is ignition-proof — suitable for fuel-present environments.\u003c\/p\u003e\n\n\u003ch3\u003eUse Cases\u003c\/h3\u003e\n\u003cp\u003eIn caravans and camper trailers, the BatteryProtect is most commonly used to protect the house battery from being flattened by the fridge, lighting, or 12V accessories while parked off-grid. At 220A rating, it handles the combined load of a compressor fridge, LED lighting, a water pump, and 12V entertainment with headroom to spare. When camp solar brings the battery back up overnight, everything reconnects automatically.\u003c\/p\u003e\n\u003cp\u003eFor 4WD touring and marine applications, the BatteryProtect is installed on the auxiliary battery to ensure that running loads — ARB fridges, winch power circuits, pumps — cannot flatten the battery to the point of a no-start. The 220A rating suits most dual-battery setups, and the IP67 electronics withstand the damp, vibration, and temperature extremes of these environments.\u003c\/p\u003e\n\n\u003ch3\u003eApp Control — VictronConnect\u003c\/h3\u003e\n\u003cp\u003eThe BatteryProtect Smart includes built-in Bluetooth Low Energy (BLE) for configuration and monitoring via the VictronConnect app (free, iOS and Android). Adjust disconnect and reconnect voltage thresholds, enable or disable the alarm output, view real-time battery voltage and unit status — all wirelessly from your phone. The Instant Readout feature lets you check live data without needing to pair the device. Bluetooth can also be disabled permanently for permanently installed systems where wireless access is not required.\u003c\/p\u003e\n\u003ch3\u003eWhy Buy From Revolution Power\u003c\/h3\u003e\n\u003cp\u003eRevolution Power is a Queensland-based Victron Energy specialist supplying caravanners, boaties, and off-grid installers across Australia. We stock the full BatteryProtect range from our Coomera, QLD warehouse and ship fast Australia-wide. Not sure which rating you need? The amp rating of your BatteryProtect must exceed the total combined current draw of all connected loads. Our team is happy to help with sizing — contact us before ordering if you're unsure.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":44799224512566,"sku":"BPR122022000","price":146.18,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/2989\/7782\/files\/Smart_20BatteryProtect_2012-24V_20220A_20_28front-angle_29.webp?v=1770624125"},{"product_id":"victron-smart-batteryprotect-48v-100a","title":"Battery Protect | Victron | Smart BatteryProtect 48V-100A","description":"\u003cp\u003eThe Victron Smart BatteryProtect 48V-100A is an automatic low-voltage disconnect device designed for 48V battery systems. Rated at 100A continuous, it sits in series between your battery bank and DC loads — protecting your battery from deep discharge by cutting load power the moment voltage drops to a programmable threshold. Once the battery recovers (via solar, mains charger, or alternator), the unit automatically reconnects. Built-in Bluetooth enables full configuration and monitoring via the VictronConnect app. Ideal for 48V off-grid solar systems, marine setups, and lithium battery installations.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eBuilt-in Bluetooth — configure and monitor via VictronConnect app (iOS \u0026amp; Android)\u003c\/li\u003e\n  \u003cli\u003eAutomatic low-voltage disconnect — protects battery from over-discharge\u003c\/li\u003e\n  \u003cli\u003eProgrammable disconnect and reconnect voltages\u003c\/li\u003e\n  \u003cli\u003e100A continuous rated \/ 250A peak\u003c\/li\u003e\n  \u003cli\u003eAlarm output with 12-second pre-disconnect warning\u003c\/li\u003e\n  \u003cli\u003eRemote on\/off input for system integration\u003c\/li\u003e\n  \u003cli\u003e90-second delayed disconnect prevents nuisance trips on short voltage dips\u003c\/li\u003e\n  \u003cli\u003eSolid-state MOSFET switching — no relays, ignition-proof, silent operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax Continuous Current\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak Current (30s)\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSystem Voltage\u003c\/td\u003e\n\u003ctd\u003e48V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e24-70V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDisconnect Voltage Range\u003c\/td\u003e\n\u003ctd\u003eProgrammable 40–58V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReconnect Voltage Range\u003c\/td\u003e\n\u003ctd\u003eProgrammable 44–62V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSelf-consumption\u003c\/td\u003e\n\u003ctd\u003e1.9 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBluetooth\u003c\/td\u003e\n\u003ctd\u003eBuilt-in Bluetooth\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eIP Rating (Electronics)\u003c\/td\u003e\n\u003ctd\u003eIP67 (fully potted)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e62 x 123 x 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eHow It Works\u003c\/h3\u003e\n\u003cp\u003eThe BatteryProtect installs in series between the battery and your DC loads — important: it protects loads only, never in the charge circuit or starter motor line. When battery voltage falls to the set disconnect threshold, the alarm output activates for 12 seconds as a warning before loads are cut after a 90-second delay. This delay prevents false trips from short-duration voltage sags under heavy starting loads. Once the charger (solar, alternator, or mains) raises the battery voltage back above the reconnect threshold, loads are automatically restored after a 30-second delay. MOSFET solid-state switching means no audible relay click, no arcing, and the unit is ignition-proof — suitable for fuel-present environments.\u003c\/p\u003e\n\n\u003ch3\u003eUse Cases\u003c\/h3\u003e\n\u003cp\u003eIn 48V off-grid solar systems, the BatteryProtect ensures your inverter, lighting, and DC loads cannot flatten the battery bank overnight. When solar generation resumes at dawn and the bank voltage recovers, all loads reconnect automatically — no manual intervention required. Pairs well with Victron MPPT chargers and GX monitors.\u003c\/p\u003e\n\u003cp\u003eOn 48V marine and commercial vessels, the BatteryProtect provides a reliable last line of defence for the house battery bank. Critical navigation equipment, bilge pumps, and communications remain protected from accidental deep discharge even when the vessel is unattended at anchor.\u003c\/p\u003e\n\n\u003ch3\u003eApp Control — VictronConnect\u003c\/h3\u003e\n\u003cp\u003eThe BatteryProtect Smart includes built-in Bluetooth Low Energy (BLE) for configuration and monitoring via the VictronConnect app (free, iOS and Android). Adjust disconnect and reconnect voltage thresholds, enable or disable the alarm output, view real-time battery voltage and unit status — all wirelessly from your phone. The Instant Readout feature lets you check live data without needing to pair the device. Bluetooth can also be disabled permanently for permanently installed systems where wireless access is not required.\u003c\/p\u003e\n\u003ch3\u003eWhy Buy From Revolution Power\u003c\/h3\u003e\n\u003cp\u003eRevolution Power is a Queensland-based Victron Energy specialist supplying caravanners, boaties, and off-grid installers across Australia. We stock the full BatteryProtect range from our Coomera, QLD warehouse and ship fast Australia-wide. Not sure which rating you need? The amp rating of your BatteryProtect must exceed the total combined current draw of all connected loads. Our team is happy to help with sizing — contact us before ordering if you're unsure.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":44799237816374,"sku":"BPR110048000","price":215.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/2989\/7782\/files\/Smart_20BatteryProtect_2048V_20100A_20_28left_29.webp?v=1770625065"},{"product_id":"victron-batteryprotect-12-24v-65a","title":"Battery Protect | Victron | BatteryProtect 12\/24V-65A","description":"\u003cp\u003eThe Victron BatteryProtect 12\/24V-65A is an automatic low-voltage disconnect (LVD) device that protects your 12V or 24V battery from deep discharge. Rated at 65A continuous, it connects in series between the battery and your DC loads — fridges, lights, pumps, entertainment systems — automatically cutting power when battery voltage drops to a programmable threshold. When the battery recovers through solar charging or alternator input, loads reconnect automatically. Configured via a 7-segment display and rotary switch on the unit. A must-have for caravans, 4WDs, and marine applications where battery protection matters.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAutomatic low-voltage disconnect — protects battery from over-discharge\u003c\/li\u003e\n  \u003cli\u003eProgrammable disconnect and reconnect voltages\u003c\/li\u003e\n  \u003cli\u003e65A continuous rated \/ 250A peak (30s surge protection)\u003c\/li\u003e\n  \u003cli\u003eAlarm output with 12-second pre-disconnect warning\u003c\/li\u003e\n  \u003cli\u003eRemote on\/off input for system integration\u003c\/li\u003e\n  \u003cli\u003e90-second delayed disconnect prevents nuisance trips on short voltage dips\u003c\/li\u003e\n  \u003cli\u003eSolid-state MOSFET switching — no relays, ignition-proof, silent operation\u003c\/li\u003e\n  \u003cli\u003eUltra-low self-consumption — 1.5 mA in normal operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax Continuous Current\u003c\/td\u003e\n\u003ctd\u003e65A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak Current (30s)\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSystem Voltage\u003c\/td\u003e\n\u003ctd\u003e12\/24V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e6-35V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDisconnect Voltage Range\u003c\/td\u003e\n\u003ctd\u003eProgrammable 10–13V (12V system) \/ 20–26V (24V system)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReconnect Voltage Range\u003c\/td\u003e\n\u003ctd\u003eProgrammable 11–14V (12V system) \/ 22–28V (24V system)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSelf-consumption\u003c\/td\u003e\n\u003ctd\u003e1.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBluetooth\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eIP Rating (Electronics)\u003c\/td\u003e\n\u003ctd\u003eIP67 (fully potted)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e40 x 48 x 106 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eHow It Works\u003c\/h3\u003e\n\u003cp\u003eThe BatteryProtect installs in series between the battery and your DC loads — important: it protects loads only, never in the charge circuit or starter motor line. When battery voltage falls to the set disconnect threshold, the alarm output activates for 12 seconds as a warning before loads are cut after a 90-second delay. This delay prevents false trips from short-duration voltage sags under heavy starting loads. Once the charger (solar, alternator, or mains) raises the battery voltage back above the reconnect threshold, loads are automatically restored after a 30-second delay. MOSFET solid-state switching means no audible relay click, no arcing, and the unit is ignition-proof — suitable for fuel-present environments.\u003c\/p\u003e\n\n\u003ch3\u003eUse Cases\u003c\/h3\u003e\n\u003cp\u003eIn caravans and camper trailers, the BatteryProtect is most commonly used to protect the house battery from being flattened by the fridge, lighting, or 12V accessories while parked off-grid. At 65A rating, it handles the combined load of a compressor fridge, LED lighting, a water pump, and 12V entertainment with headroom to spare. When camp solar brings the battery back up overnight, everything reconnects automatically.\u003c\/p\u003e\n\u003cp\u003eFor 4WD touring and marine applications, the BatteryProtect is installed on the auxiliary battery to ensure that running loads — ARB fridges, winch power circuits, pumps — cannot flatten the battery to the point of a no-start. The 65A rating suits most dual-battery setups, and the IP67 electronics withstand the damp, vibration, and temperature extremes of these environments.\u003c\/p\u003e\n\n\u003ch3\u003eWhy Buy From Revolution Power\u003c\/h3\u003e\n\u003cp\u003eRevolution Power is a Queensland-based Victron Energy specialist supplying caravanners, boaties, and off-grid installers across Australia. We stock the full BatteryProtect range from our Coomera, QLD warehouse and ship fast Australia-wide. Not sure which rating you need? The amp rating of your BatteryProtect must exceed the total combined current draw of all connected loads. Our team is happy to help with sizing — contact us before ordering if you're unsure.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":44799242633270,"sku":"BPR000065400","price":51.89,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/2989\/7782\/files\/BatteryProtect_2012-24V_2065A_20_28front_29.webp?v=1770626707"},{"product_id":"victron-batteryprotect-12-24v-100a","title":"Battery Protect | Victron | BatteryProtect 12\/24V-100A","description":"\u003cp\u003eThe Victron BatteryProtect 12\/24V-100A is an automatic low-voltage disconnect (LVD) device that protects your 12V or 24V battery from deep discharge. Rated at 100A continuous, it connects in series between the battery and your DC loads — fridges, lights, pumps, entertainment systems — automatically cutting power when battery voltage drops to a programmable threshold. When the battery recovers through solar charging or alternator input, loads reconnect automatically. Configured via a 7-segment display and rotary switch on the unit. A must-have for caravans, 4WDs, and marine applications where battery protection matters.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAutomatic low-voltage disconnect — protects battery from over-discharge\u003c\/li\u003e\n  \u003cli\u003eProgrammable disconnect and reconnect voltages\u003c\/li\u003e\n  \u003cli\u003e100A continuous rated \/ 600A peak (30s surge protection)\u003c\/li\u003e\n  \u003cli\u003eAlarm output with 12-second pre-disconnect warning\u003c\/li\u003e\n  \u003cli\u003eRemote on\/off input for system integration\u003c\/li\u003e\n  \u003cli\u003e90-second delayed disconnect prevents nuisance trips on short voltage dips\u003c\/li\u003e\n  \u003cli\u003eSolid-state MOSFET switching — no relays, ignition-proof, silent operation\u003c\/li\u003e\n  \u003cli\u003eUltra-low self-consumption — 1.5 mA in normal operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax Continuous Current\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak Current (30s)\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSystem Voltage\u003c\/td\u003e\n\u003ctd\u003e12\/24V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e6-35V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDisconnect Voltage Range\u003c\/td\u003e\n\u003ctd\u003eProgrammable 10–13V (12V) \/ 20–26V (24V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReconnect Voltage Range\u003c\/td\u003e\n\u003ctd\u003eProgrammable 11–14V (12V) \/ 22–28V (24V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSelf-consumption\u003c\/td\u003e\n\u003ctd\u003e1.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBluetooth\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eIP Rating (Electronics)\u003c\/td\u003e\n\u003ctd\u003eIP67 (fully potted)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e59 x 42 x 115 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eHow It Works\u003c\/h3\u003e\n\u003cp\u003eThe BatteryProtect installs in series between the battery and your DC loads — important: it protects loads only, never in the charge circuit or starter motor line. When battery voltage falls to the set disconnect threshold, the alarm output activates for 12 seconds as a warning before loads are cut after a 90-second delay. This delay prevents false trips from short-duration voltage sags under heavy starting loads. Once the charger (solar, alternator, or mains) raises the battery voltage back above the reconnect threshold, loads are automatically restored after a 30-second delay. MOSFET solid-state switching means no audible relay click, no arcing, and the unit is ignition-proof — suitable for fuel-present environments.\u003c\/p\u003e\n\n\u003ch3\u003eUse Cases\u003c\/h3\u003e\n\u003cp\u003eIn caravans and camper trailers, the BatteryProtect is most commonly used to protect the house battery from being flattened by the fridge, lighting, or 12V accessories while parked off-grid. At 100A rating, it handles the combined load of a compressor fridge, LED lighting, a water pump, and 12V entertainment with headroom to spare. When camp solar brings the battery back up overnight, everything reconnects automatically.\u003c\/p\u003e\n\u003cp\u003eFor 4WD touring and marine applications, the BatteryProtect is installed on the auxiliary battery to ensure that running loads — ARB fridges, winch power circuits, pumps — cannot flatten the battery to the point of a no-start. The 100A rating suits most dual-battery setups, and the IP67 electronics withstand the damp, vibration, and temperature extremes of these environments.\u003c\/p\u003e\n\n\u003ch3\u003eWhy Buy From Revolution Power\u003c\/h3\u003e\n\u003cp\u003eRevolution Power is a Queensland-based Victron Energy specialist supplying caravanners, boaties, and off-grid installers across Australia. We stock the full BatteryProtect range from our Coomera, QLD warehouse and ship fast Australia-wide. Not sure which rating you need? The amp rating of your BatteryProtect must exceed the total combined current draw of all connected loads. Our team is happy to help with sizing — contact us before ordering if you're unsure.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":44799272452150,"sku":"BPR000100400","price":76.17,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/2989\/7782\/files\/BPR000100400_BatteryProtect_2012-24V-100A_20_28front-low_29.webp?v=1770627174"},{"product_id":"victron-batteryprotect-12-24v-220a","title":"Battery Protect | Victron | BatteryProtect 12\/24V-220A","description":"\u003cp\u003eThe Victron BatteryProtect 12\/24V-220A is an automatic low-voltage disconnect (LVD) device that protects your 12V or 24V battery from deep discharge. Rated at 220A continuous, it connects in series between the battery and your DC loads — fridges, lights, pumps, entertainment systems — automatically cutting power when battery voltage drops to a programmable threshold. When the battery recovers through solar charging or alternator input, loads reconnect automatically. Configured via a 7-segment display and rotary switch on the unit. A must-have for caravans, 4WDs, and marine applications where battery protection matters.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAutomatic low-voltage disconnect — protects battery from over-discharge\u003c\/li\u003e\n  \u003cli\u003eProgrammable disconnect and reconnect voltages\u003c\/li\u003e\n  \u003cli\u003e220A continuous rated \/ 600A peak (30s surge protection)\u003c\/li\u003e\n  \u003cli\u003eAlarm output with 12-second pre-disconnect warning\u003c\/li\u003e\n  \u003cli\u003eRemote on\/off input for system integration\u003c\/li\u003e\n  \u003cli\u003e90-second delayed disconnect prevents nuisance trips on short voltage dips\u003c\/li\u003e\n  \u003cli\u003eSolid-state MOSFET switching — no relays, ignition-proof, silent operation\u003c\/li\u003e\n  \u003cli\u003eUltra-low self-consumption — 1.5 mA in normal operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax Continuous Current\u003c\/td\u003e\n\u003ctd\u003e220A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak Current (30s)\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSystem Voltage\u003c\/td\u003e\n\u003ctd\u003e12\/24V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e6-35V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDisconnect Voltage Range\u003c\/td\u003e\n\u003ctd\u003eProgrammable 10–13V (12V) \/ 20–26V (24V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReconnect Voltage Range\u003c\/td\u003e\n\u003ctd\u003eProgrammable 11–14V (12V) \/ 22–28V (24V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSelf-consumption\u003c\/td\u003e\n\u003ctd\u003e1.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBluetooth\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eIP Rating (Electronics)\u003c\/td\u003e\n\u003ctd\u003eIP67 (fully potted)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e62 x 123 x 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eHow It Works\u003c\/h3\u003e\n\u003cp\u003eThe BatteryProtect installs in series between the battery and your DC loads — important: it protects loads only, never in the charge circuit or starter motor line. When battery voltage falls to the set disconnect threshold, the alarm output activates for 12 seconds as a warning before loads are cut after a 90-second delay. This delay prevents false trips from short-duration voltage sags under heavy starting loads. Once the charger (solar, alternator, or mains) raises the battery voltage back above the reconnect threshold, loads are automatically restored after a 30-second delay. MOSFET solid-state switching means no audible relay click, no arcing, and the unit is ignition-proof — suitable for fuel-present environments.\u003c\/p\u003e\n\n\u003ch3\u003eUse Cases\u003c\/h3\u003e\n\u003cp\u003eIn caravans and camper trailers, the BatteryProtect is most commonly used to protect the house battery from being flattened by the fridge, lighting, or 12V accessories while parked off-grid. At 220A rating, it handles the combined load of a compressor fridge, LED lighting, a water pump, and 12V entertainment with headroom to spare. When camp solar brings the battery back up overnight, everything reconnects automatically.\u003c\/p\u003e\n\u003cp\u003eFor 4WD touring and marine applications, the BatteryProtect is installed on the auxiliary battery to ensure that running loads — ARB fridges, winch power circuits, pumps — cannot flatten the battery to the point of a no-start. The 220A rating suits most dual-battery setups, and the IP67 electronics withstand the damp, vibration, and temperature extremes of these environments.\u003c\/p\u003e\n\n\u003ch3\u003eWhy Buy From Revolution Power\u003c\/h3\u003e\n\u003cp\u003eRevolution Power is a Queensland-based Victron Energy specialist supplying caravanners, boaties, and off-grid installers across Australia. We stock the full BatteryProtect range from our Coomera, QLD warehouse and ship fast Australia-wide. Not sure which rating you need? The amp rating of your BatteryProtect must exceed the total combined current draw of all connected loads. Our team is happy to help with sizing — contact us before ordering if you're unsure.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":44799278383158,"sku":"BPR000220400","price":184.23,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/2989\/7782\/files\/BatteryProtect_2048V_20100A_20_28front-angle_29.webp?v=1770629010"},{"product_id":"victron-batteryprotect-48v-100a","title":"Battery Protect | Victron | BatteryProtect 48V-100A","description":"\u003cp\u003eThe Victron BatteryProtect 48V-100A is an automatic low-voltage disconnect device designed for 48V battery systems. Rated at 100A continuous, it sits in series between your battery bank and DC loads — protecting your battery from deep discharge by cutting load power the moment voltage drops to a programmable threshold. Once the battery recovers (via solar, mains charger, or alternator), the unit automatically reconnects. Configured via a rotary switch and 7-segment display. Ideal for 48V off-grid solar systems, marine setups, and lithium battery installations.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAutomatic low-voltage disconnect — protects battery from over-discharge\u003c\/li\u003e\n  \u003cli\u003eProgrammable disconnect and reconnect voltages\u003c\/li\u003e\n  \u003cli\u003e100A continuous rated \/ 250A peak\u003c\/li\u003e\n  \u003cli\u003eAlarm output with 12-second pre-disconnect warning\u003c\/li\u003e\n  \u003cli\u003eRemote on\/off input for system integration\u003c\/li\u003e\n  \u003cli\u003e90-second delayed disconnect prevents nuisance trips on short voltage dips\u003c\/li\u003e\n  \u003cli\u003eSolid-state MOSFET switching — no relays, ignition-proof, silent operation\u003c\/li\u003e\n  \u003cli\u003eUltra-low self-consumption — 1.5 mA in normal operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax Continuous Current\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak Current (30s)\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSystem Voltage\u003c\/td\u003e\n\u003ctd\u003e48V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e24-64V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDisconnect Voltage Range\u003c\/td\u003e\n\u003ctd\u003eProgrammable 40–58V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReconnect Voltage Range\u003c\/td\u003e\n\u003ctd\u003eProgrammable 44–62V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSelf-consumption\u003c\/td\u003e\n\u003ctd\u003e2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBluetooth\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eIP Rating (Electronics)\u003c\/td\u003e\n\u003ctd\u003eIP67 (fully potted)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e62 x 123 x 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eHow It Works\u003c\/h3\u003e\n\u003cp\u003eThe BatteryProtect installs in series between the battery and your DC loads — important: it protects loads only, never in the charge circuit or starter motor line. When battery voltage falls to the set disconnect threshold, the alarm output activates for 12 seconds as a warning before loads are cut after a 90-second delay. This delay prevents false trips from short-duration voltage sags under heavy starting loads. Once the charger (solar, alternator, or mains) raises the battery voltage back above the reconnect threshold, loads are automatically restored after a 30-second delay. MOSFET solid-state switching means no audible relay click, no arcing, and the unit is ignition-proof — suitable for fuel-present environments.\u003c\/p\u003e\n\n\u003ch3\u003eUse Cases\u003c\/h3\u003e\n\u003cp\u003eIn 48V off-grid solar systems, the BatteryProtect ensures your inverter, lighting, and DC loads cannot flatten the battery bank overnight. When solar generation resumes at dawn and the bank voltage recovers, all loads reconnect automatically — no manual intervention required. Pairs well with Victron MPPT chargers and GX monitors.\u003c\/p\u003e\n\u003cp\u003eOn 48V marine and commercial vessels, the BatteryProtect provides a reliable last line of defence for the house battery bank. Critical navigation equipment, bilge pumps, and communications remain protected from accidental deep discharge even when the vessel is unattended at anchor.\u003c\/p\u003e\n\n\u003ch3\u003eWhy Buy From Revolution Power\u003c\/h3\u003e\n\u003cp\u003eRevolution Power is a Queensland-based Victron Energy specialist supplying caravanners, boaties, and off-grid installers across Australia. We stock the full BatteryProtect range from our Coomera, QLD warehouse and ship fast Australia-wide. Not sure which rating you need? The amp rating of your BatteryProtect must exceed the total combined current draw of all connected loads. Our team is happy to help with sizing — contact us before ordering if you're unsure.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":44799306727478,"sku":"BPR048100400","price":184.23,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/2989\/7782\/files\/BatteryProtect_2048V_20100A_20_28front-angle_29_e96f4d4d-1af3-4d69-bddd-41881ca9da5c.webp?v=1770629518"},{"product_id":"victron-lynx-power-in-m8","title":"Lynx Busbar | Victron | Lynx Power In (M8)","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 – 60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported System Voltages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12, 24 or 48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Continuous Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 (positive and negative, unfused)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBusbar Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (no fuses in this module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABS plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e290 × 170 × 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBusbar Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTinned copper, 8 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":44837160190006,"sku":"LYN020102000","price":235.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/2989\/7782\/files\/Lynx_Power_in_left_LYN020102000_jpg.webp?v=1771454364"},{"product_id":"victron-lynx-power-in-m10","title":"Lynx Busbar | Victron | Lynx Power In (M10)","description":"\u003cp\u003eThe Victron Lynx Power In (M10) is the battery connection point at the heart of the modular Lynx busbar system. It provides a robust, high-current DC input from your battery bank into the Lynx distribution chain, with heavy-duty busbars rated to 1000A continuous. As part of Victron's snap-together Lynx family, the Power In (M10) connects side-by-side with Lynx Distributors, Lynx Shunts, and Lynx Smart BMS modules to form a clean, professional DC distribution centre.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1000A continuous current rating — handles the largest lithium and lead-acid battery banks\u003c\/li\u003e\n  \u003cli\u003eM10 battery terminal connection for secure, high-torque lug attachment\u003c\/li\u003e\n  \u003cli\u003eModular Lynx snap-together design — mounts directly beside Lynx Distributor, Shunt, or Smart BMS\u003c\/li\u003e\n  \u003cli\u003eIP21 rated housing — suitable for engine rooms, battery compartments, and switchboards\u003c\/li\u003e\n  \u003cli\u003ePositive and negative busbars exposed for easy downstream connection\u003c\/li\u003e\n  \u003cli\u003eCompact, uniform footprint — integrates cleanly into panel or rack installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax Current\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003eUp to 48V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTerminal Size\u003c\/td\u003e\n\u003ctd\u003eM10\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e170 x 290 x 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eLynx System Integration\u003c\/h3\u003e\n\u003cp\u003eThe Lynx product family uses a modular snap-together design — individual Lynx units connect side-by-side to form a clean, safe high-current DC distribution centre. Combine a Lynx Power In, Lynx Distributor, and Lynx Shunt to create a compact, professional battery management hub for your system.\u003c\/p\u003e\n\n\u003ch3\u003eUse Cases\u003c\/h3\u003e\n\u003cp\u003eIn off-grid and solar storage systems, the Lynx Power In provides the main positive and negative connection point for your battery bank, feeding current cleanly into fused distribution or a battery monitoring shunt. Using the modular Lynx system keeps high-current wiring contained, labelled, and accessible for maintenance — an important safety consideration in any large energy storage installation. Whether your bank is 100Ah or 1000Ah, the Lynx Power In handles the full continuous load without derating.\u003c\/p\u003e\n\u003cp\u003eFor marine and motorhome applications, the Lynx Power In's compact IP21 enclosure fits neatly in switchboard cabinets, engine rooms, and battery compartments. The M10 terminals handle large-gauge cable lugs required for high-current 12V, 24V, and 48V systems. The snap-together Lynx system eliminates the need for custom copper busbars, saving installation time and cost — a meaningful advantage in confined build spaces where neat, certified wiring is both a safety and resale requirement.\u003c\/p\u003e\n\n\u003ch3\u003eWhy Buy From Revolution Power\u003c\/h3\u003e\n\u003cp\u003eRevolution Power is a Queensland-based Victron Energy specialist. Fast shipping Australia-wide from Coomera, QLD. Contact us for advice on which Lynx combination suits your battery bank and load requirements.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":44837160288310,"sku":"LYN020102010","price":202.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/2989\/7782\/files\/Lynx_20Power_20in_20_28M10_29_20_28front_29.webp?v=1771454498"},{"product_id":"victron-lynx-smart-bms-500-m8","title":"Lynx Busbar | Victron | Lynx Smart BMS 500 (M10)","description":"\u003cp\u003eThe Victron Lynx Smart BMS 500 (M10) is a high-current Battery Management System designed specifically for Victron Lithium Smart batteries. Combining busbar, BMS, and VE.Can\/VE.Direct connectivity in a single Lynx-compatible module, it protects your lithium battery bank from over-charge, over-discharge, over-temperature, and short circuit while integrating seamlessly into any Victron GX-based system.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e500A continuous current rating — sized for medium to large Victron lithium battery banks\u003c\/li\u003e\n  \u003cli\u003eFull BMS protection: over-charge, over-discharge, over-temperature, short circuit, and cell balancing\u003c\/li\u003e\n  \u003cli\u003eVE.Can and VE.Direct communication — integrates with Cerbo GX, Ekrano GX, and Venus GX\u003c\/li\u003e\n  \u003cli\u003ePre-alarm outputs alert the system before a protection event disconnects loads\u003c\/li\u003e\n  \u003cli\u003eModular Lynx snap-together design — mounts directly alongside Lynx Power In and Lynx Distributor\u003c\/li\u003e\n  \u003cli\u003eWorks exclusively with Victron Lithium Smart batteries (12.8V and 25.6V series)\u003c\/li\u003e\n  \u003cli\u003eIP21 rated enclosure — suitable for battery rooms, switchboards, and vehicle battery compartments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax Current\u003c\/td\u003e\n\u003ctd\u003e500A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eVE.Can, VE.Direct\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003eUp to 48V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTerminal Size\u003c\/td\u003e\n\u003ctd\u003eM10\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e170 x 186 x 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eLynx System Integration\u003c\/h3\u003e\n\u003cp\u003eThe Lynx product family uses a modular snap-together design — individual Lynx units connect side-by-side to form a clean, safe high-current DC distribution centre. Combine a Lynx Power In, Lynx Distributor, and Lynx Shunt to create a compact, professional battery management hub for your system.\u003c\/p\u003e\n\n\u003ch3\u003eUse Cases\u003c\/h3\u003e\n\u003cp\u003eFor off-grid solar systems using Victron Lithium Smart batteries, the Lynx Smart BMS 500 provides fully automated cell-level protection that keeps your expensive lithium bank safe under all operating conditions. Pair with a Cerbo GX to monitor individual cell voltages, SoC, and temperature remotely via VRM — giving you confidence your off-grid system is protected 24\/7 without manual intervention. The BMS handles both charging and discharging protection, and integrates directly into Victron's ESS (Energy Storage System) software framework.\u003c\/p\u003e\n\u003cp\u003eOn marine and motorhome builds using Victron lithium batteries, the Lynx Smart BMS delivers certified BMS protection in a compact, snap-fit busbar form factor. The pre-alarm output warns your GX device before the BMS trips, giving generators or shore chargers time to respond — protecting both the battery bank and connected loads from unexpected disconnection underway. The M10 terminals accommodate the heavy-gauge cabling required for high-current lithium systems in demanding mobile and marine environments.\u003c\/p\u003e\n\n\u003ch3\u003eWhy Buy From Revolution Power\u003c\/h3\u003e\n\u003cp\u003eRevolution Power is a Queensland-based Victron Energy specialist. Fast shipping Australia-wide from Coomera, QLD. Contact us for advice on which Lynx combination suits your battery bank and load requirements.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":44837164908598,"sku":"LYN034160210","price":1145.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/2989\/7782\/files\/Lynx-Smart-BMS-_28top-with-accessories_29.webp?v=1771454779"},{"product_id":"victron-lynx-smart-bms-1000-m10","title":"Lynx Busbar | Victron | Lynx Smart BMS 1000 (M10)","description":"\u003cp\u003eThe Victron Lynx Smart BMS 1000 (M10) is a high-current Battery Management System designed specifically for Victron Lithium Smart batteries. Combining busbar, BMS, and VE.Can\/VE.Direct connectivity in a single Lynx-compatible module, it protects your lithium battery bank from over-charge, over-discharge, over-temperature, and short circuit while integrating seamlessly into any Victron GX-based system.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1000A continuous current rating — sized for medium to large Victron lithium battery banks\u003c\/li\u003e\n  \u003cli\u003eFull BMS protection: over-charge, over-discharge, over-temperature, short circuit, and cell balancing\u003c\/li\u003e\n  \u003cli\u003eVE.Can and VE.Direct communication — integrates with Cerbo GX, Ekrano GX, and Venus GX\u003c\/li\u003e\n  \u003cli\u003ePre-alarm outputs alert the system before a protection event disconnects loads\u003c\/li\u003e\n  \u003cli\u003eModular Lynx snap-together design — mounts directly alongside Lynx Power In and Lynx Distributor\u003c\/li\u003e\n  \u003cli\u003eWorks exclusively with Victron Lithium Smart batteries (12.8V and 25.6V series)\u003c\/li\u003e\n  \u003cli\u003eIP21 rated enclosure — suitable for battery rooms, switchboards, and vehicle battery compartments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax Current\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eVE.Can, VE.Direct\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003eUp to 48V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTerminal Size\u003c\/td\u003e\n\u003ctd\u003eM10\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e170 x 186 x 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eLynx System Integration\u003c\/h3\u003e\n\u003cp\u003eThe Lynx product family uses a modular snap-together design — individual Lynx units connect side-by-side to form a clean, safe high-current DC distribution centre. Combine a Lynx Power In, Lynx Distributor, and Lynx Shunt to create a compact, professional battery management hub for your system.\u003c\/p\u003e\n\n\u003ch3\u003eUse Cases\u003c\/h3\u003e\n\u003cp\u003eFor off-grid solar systems using Victron Lithium Smart batteries, the Lynx Smart BMS 1000 provides fully automated cell-level protection that keeps your expensive lithium bank safe under all operating conditions. Pair with a Cerbo GX to monitor individual cell voltages, SoC, and temperature remotely via VRM — giving you confidence your off-grid system is protected 24\/7 without manual intervention. The BMS handles both charging and discharging protection, and integrates directly into Victron's ESS (Energy Storage System) software framework.\u003c\/p\u003e\n\u003cp\u003eOn marine and motorhome builds using Victron lithium batteries, the Lynx Smart BMS delivers certified BMS protection in a compact, snap-fit busbar form factor. The pre-alarm output warns your GX device before the BMS trips, giving generators or shore chargers time to respond — protecting both the battery bank and connected loads from unexpected disconnection underway. The M10 terminals accommodate the heavy-gauge cabling required for high-current lithium systems in demanding mobile and marine environments.\u003c\/p\u003e\n\n\u003ch3\u003eWhy Buy From Revolution Power\u003c\/h3\u003e\n\u003cp\u003eRevolution Power is a Queensland-based Victron Energy specialist. Fast shipping Australia-wide from Coomera, QLD. Contact us for advice on which Lynx combination suits your battery bank and load requirements.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":44837204164662,"sku":"LYN034170210","price":1499.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/2989\/7782\/files\/Lynx_20Smart_20BMS_201000_20_28M10_29_20_28top_29.webp?v=1771454974"},{"product_id":"victron-lynx-smart-bms-500-ng-m10","title":"Lynx Busbar | Victron | Lynx Smart BMS 500 NG (M10)","description":"\u003cp\u003eThe Victron Lynx Smart BMS 500 NG (M10) is a high-current Battery Management System designed specifically for Victron Lithium Smart batteries. Combining busbar, BMS, and VE.Can\/VE.Direct connectivity in a single Lynx-compatible module, it protects your lithium battery bank from over-charge, over-discharge, over-temperature, and short circuit while integrating seamlessly into any Victron GX-based system. The NG (Next Generation) edition includes updated firmware, improved BMS algorithms, and enhanced compatibility with the latest Victron GX devices.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e500A continuous current rating — sized for medium to large Victron lithium battery banks\u003c\/li\u003e\n  \u003cli\u003eFull BMS protection: over-charge, over-discharge, over-temperature, short circuit, and cell balancing\u003c\/li\u003e\n  \u003cli\u003eVE.Can and VE.Direct communication — integrates with Cerbo GX, Ekrano GX, and Venus GX\u003c\/li\u003e\n  \u003cli\u003ePre-alarm outputs alert the system before a protection event disconnects loads\u003c\/li\u003e\n  \u003cli\u003eModular Lynx snap-together design — mounts directly alongside Lynx Power In and Lynx Distributor\u003c\/li\u003e\n  \u003cli\u003eWorks exclusively with Victron Lithium Smart batteries (12.8V and 25.6V series)\u003c\/li\u003e\n  \u003cli\u003eIP21 rated enclosure — suitable for battery rooms, switchboards, and vehicle battery compartments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax Current\u003c\/td\u003e\n\u003ctd\u003e500A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eVE.Can, VE.Direct\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003eUp to 48V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTerminal Size\u003c\/td\u003e\n\u003ctd\u003eM10\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e170 x 186 x 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eLynx System Integration\u003c\/h3\u003e\n\u003cp\u003eThe Lynx product family uses a modular snap-together design — individual Lynx units connect side-by-side to form a clean, safe high-current DC distribution centre. Combine a Lynx Power In, Lynx Distributor, and Lynx Shunt to create a compact, professional battery management hub for your system.\u003c\/p\u003e\n\n\u003ch3\u003eUse Cases\u003c\/h3\u003e\n\u003cp\u003eFor off-grid solar systems using Victron Lithium Smart batteries, the Lynx Smart BMS 500 NG provides fully automated cell-level protection that keeps your expensive lithium bank safe under all operating conditions. Pair with a Cerbo GX to monitor individual cell voltages, SoC, and temperature remotely via VRM — giving you confidence your off-grid system is protected 24\/7 without manual intervention. The BMS handles both charging and discharging protection, and integrates directly into Victron's ESS (Energy Storage System) software framework.\u003c\/p\u003e\n\u003cp\u003eOn marine and motorhome builds using Victron lithium batteries, the Lynx Smart BMS NG delivers certified BMS protection in a compact, snap-fit busbar form factor. The pre-alarm output warns your GX device before the BMS trips, giving generators or shore chargers time to respond — protecting both the battery bank and connected loads from unexpected disconnection underway. The M10 terminals accommodate the heavy-gauge cabling required for high-current lithium systems in demanding mobile and marine environments.\u003c\/p\u003e\n\n\u003ch3\u003eWhy Buy From Revolution Power\u003c\/h3\u003e\n\u003cp\u003eRevolution Power is a Queensland-based Victron Energy specialist. Fast shipping Australia-wide from Coomera, QLD. Contact us for advice on which Lynx combination suits your battery bank and load requirements.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":44837262393398,"sku":"LYN034160310","price":1159.2,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/2989\/7782\/files\/Lynx_20Smart_20BMS_20500_20NG_20_28M10_29_20_28top_29.webp?v=1771455145"},{"product_id":"victron-lynx-smart-bms-1000-ng-m10","title":"Lynx Busbar | Victron | Lynx Smart BMS 1000 NG (M10)","description":"\u003cp\u003eThe Victron Lynx Smart BMS 1000 NG (M10) is a high-current Battery Management System designed specifically for Victron Lithium Smart batteries. Combining busbar, BMS, and VE.Can\/VE.Direct connectivity in a single Lynx-compatible module, it protects your lithium battery bank from over-charge, over-discharge, over-temperature, and short circuit while integrating seamlessly into any Victron GX-based system. The NG (Next Generation) edition includes updated firmware, improved BMS algorithms, and enhanced compatibility with the latest Victron GX devices.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1000A continuous current rating — sized for medium to large Victron lithium battery banks\u003c\/li\u003e\n  \u003cli\u003eFull BMS protection: over-charge, over-discharge, over-temperature, short circuit, and cell balancing\u003c\/li\u003e\n  \u003cli\u003eVE.Can and VE.Direct communication — integrates with Cerbo GX, Ekrano GX, and Venus GX\u003c\/li\u003e\n  \u003cli\u003ePre-alarm outputs alert the system before a protection event disconnects loads\u003c\/li\u003e\n  \u003cli\u003eModular Lynx snap-together design — mounts directly alongside Lynx Power In and Lynx Distributor\u003c\/li\u003e\n  \u003cli\u003eWorks exclusively with Victron Lithium Smart batteries (12.8V and 25.6V series)\u003c\/li\u003e\n  \u003cli\u003eIP21 rated enclosure — suitable for battery rooms, switchboards, and vehicle battery compartments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax Current\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eVE.Can, VE.Direct\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003eUp to 48V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTerminal Size\u003c\/td\u003e\n\u003ctd\u003eM10\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e170 x 186 x 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eLynx System Integration\u003c\/h3\u003e\n\u003cp\u003eThe Lynx product family uses a modular snap-together design — individual Lynx units connect side-by-side to form a clean, safe high-current DC distribution centre. Combine a Lynx Power In, Lynx Distributor, and Lynx Shunt to create a compact, professional battery management hub for your system.\u003c\/p\u003e\n\n\u003ch3\u003eUse Cases\u003c\/h3\u003e\n\u003cp\u003eFor off-grid solar systems using Victron Lithium Smart batteries, the Lynx Smart BMS 1000 NG provides fully automated cell-level protection that keeps your expensive lithium bank safe under all operating conditions. Pair with a Cerbo GX to monitor individual cell voltages, SoC, and temperature remotely via VRM — giving you confidence your off-grid system is protected 24\/7 without manual intervention. The BMS handles both charging and discharging protection, and integrates directly into Victron's ESS (Energy Storage System) software framework.\u003c\/p\u003e\n\u003cp\u003eOn marine and motorhome builds using Victron lithium batteries, the Lynx Smart BMS NG delivers certified BMS protection in a compact, snap-fit busbar form factor. The pre-alarm output warns your GX device before the BMS trips, giving generators or shore chargers time to respond — protecting both the battery bank and connected loads from unexpected disconnection underway. The M10 terminals accommodate the heavy-gauge cabling required for high-current lithium systems in demanding mobile and marine environments.\u003c\/p\u003e\n\n\u003ch3\u003eWhy Buy From Revolution Power\u003c\/h3\u003e\n\u003cp\u003eRevolution Power is a Queensland-based Victron Energy specialist. Fast shipping Australia-wide from Coomera, QLD. Contact us for advice on which Lynx combination suits your battery bank and load requirements.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":44837315936310,"sku":"LYN034170310","price":1384.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/2989\/7782\/files\/Lynx_20Smart_20BMS_201000_20NG_20_28M10_29_20_28top_29.webp?v=1771455396"},{"product_id":"victron-lynx-distributor-m10","title":"Lynx Busbar | Victron | Lynx Distributor (M10)","description":"\u003cp\u003eThe Victron Lynx Distributor (M10) is a high-current DC distribution busbar with four fuse positions, designed to safely distribute power from your battery bank to multiple load circuits or Victron components. Part of the modular Lynx busbar family, it accepts Mega\/Class-T fuses up to 400A per slot and snaps directly to adjacent Lynx modules — creating a tidy, professional DC distribution centre without custom copper busbars or separate fuse holders.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e4x fuse positions — accept Mega fuses or Class-T fuses up to 400A each\u003c\/li\u003e\n  \u003cli\u003e1000A continuous busbar rating — supports even the largest battery banks and inverters\u003c\/li\u003e\n  \u003cli\u003eM10 terminal connections for secure, high-torque lug attachment to main busbars\u003c\/li\u003e\n  \u003cli\u003eModular snap-together design — connects directly to Lynx Power In, Lynx Shunt, and Lynx Smart BMS\u003c\/li\u003e\n  \u003cli\u003eLED fuse-blown indicators — visually identify a blown fuse without a multimeter\u003c\/li\u003e\n  \u003cli\u003eIP21 rated enclosure — suitable for engine rooms, switchboards, and battery compartments\u003c\/li\u003e\n  \u003cli\u003eIndividual load circuit output connections — clean distribution to inverters, chargers, and loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax Current\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFuse Slots\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax Fuse Size\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003eUp to 48V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTerminal Size\u003c\/td\u003e\n\u003ctd\u003eM10\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e170 x 290 x 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eLynx System Integration\u003c\/h3\u003e\n\u003cp\u003eThe Lynx product family uses a modular snap-together design — individual Lynx units connect side-by-side to form a clean, safe high-current DC distribution centre. Combine a Lynx Power In, Lynx Distributor, and Lynx Shunt to create a compact, professional battery management hub for your system.\u003c\/p\u003e\n\n\u003ch3\u003eUse Cases\u003c\/h3\u003e\n\u003cp\u003eIn off-grid solar installations, the Lynx Distributor sits between the battery bank and multiple high-current loads — MultiPlus inverter\/chargers, DC-DC converters, and large MPPT chargers each get their own individually fused output. With LED blow indicators and a lockable cover, the Distributor makes fault-finding and maintenance straightforward even in remote locations. Having individually fused outputs also means a single load fault cannot take down the entire system — a critical reliability feature for unattended installations.\u003c\/p\u003e\n\u003cp\u003eFor marine and motorhome systems, the Lynx Distributor (M10) provides a tidy, certified fused distribution point that meets marine and automotive electrical standards. Replace a wall of individual fuse holders with one compact modular unit that snap-fits to your existing Lynx Power In or Shunt, significantly reducing the wiring footprint inside tight cabinetry. The lockable transparent cover keeps connections safe from accidental contact while still allowing visual inspection of fuse status during routine checks.\u003c\/p\u003e\n\n\u003ch3\u003eWhy Buy From Revolution Power\u003c\/h3\u003e\n\u003cp\u003eRevolution Power is a Queensland-based Victron Energy specialist. Fast shipping Australia-wide from Coomera, QLD. Contact us for advice on which Lynx combination suits your battery bank and load requirements.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":44837322489910,"sku":"LYN060102010","price":293.08,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/2989\/7782\/files\/Lynx_20distributor_20_28M10_29_20_28left_29.webp?v=1771455626"},{"product_id":"victron-lynx-distributor-m8","title":"Lynx Busbar | Victron | Lynx Distributor (M8)","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 – 60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported System Voltages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12, 24 or 48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Continuous Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReverse Polarity Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (excluding RJ10 cable connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum 100 mA (with all LEDs illuminated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Fused Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 (positive side, MEGA fuse each)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Negative Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 negative + 1 ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMEGA fuse (M8; purchased separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBusbar Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\/Data Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ10 (40 cm cable included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes — blown fuse detection via LED + alarm to Lynx Smart BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABS plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × L × W)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e290 × 170 × 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBusbar Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTinned copper, 8 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":44837328617526,"sku":"LYN060102000","price":293.08,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/2989\/7782\/files\/download.webp?v=1771455873"},{"product_id":"victron-lynx-shunt-ve-can-m8","title":"Lynx Busbar | Victron | Lynx Shunt VE.Can (M8)","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 – 70 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported System Voltages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12, 24 or 48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Continuous Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReverse Polarity Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 mA @ 12V; 33 mA @ 24V; 20 mA @ 48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePotential-free, 3 A \/ 30 V DC \/ 250 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Type (M8 model)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCNN fuse (purchased separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBusbar Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Dummy Busbar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot included on M8 model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVE.Can Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ45 (two RJ45 terminators included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRJ10 Power Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTo Lynx Distributor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew terminal (sensor included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Monitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes — integrated shunt-based battery monitor via VE.Can to GX device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABS plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e190 × 180 × 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBusbar Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTinned copper, 8 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":44837333499958,"sku":"LYN040102100","price":505.9,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/2989\/7782\/files\/Lynx_Shunt_1000A_right_LYN040102000.webp?v=1771455968"},{"product_id":"victron-lynx-shunt-ve-can-m10","title":"Lynx Busbar | Victron | Lynx Shunt VE.Can (M10)","description":"\u003cp\u003eThe Victron Lynx Shunt VE.Can (M10) is an integrated battery monitor and high-current busbar module in one compact Lynx-compatible housing. It measures current up to 1000A on the main DC bus and communicates battery state of charge, voltage, current, power, and consumed amp-hours to a connected GX device (Cerbo GX, Ekrano GX, Venus GX) via VE.Can — providing live battery data in the VRM portal and local GX display with no separate battery monitor wiring required.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1000A continuous current measurement — accurately monitors large lithium and lead-acid battery banks\u003c\/li\u003e\n  \u003cli\u003eVE.Can communication — direct integration with all Cerbo GX, Ekrano GX, and Venus GX devices\u003c\/li\u003e\n  \u003cli\u003eDisplays voltage, current, power, state of charge, and time-to-go via connected GX device\u003c\/li\u003e\n  \u003cli\u003eM10 terminal connections for heavy-duty main busbar connection\u003c\/li\u003e\n  \u003cli\u003eModular snap-together Lynx design — mounts alongside Lynx Power In and Lynx Distributor modules\u003c\/li\u003e\n  \u003cli\u003eIP21 rated enclosure — suitable for battery rooms, engine rooms, and switchboard cabinets\u003c\/li\u003e\n  \u003cli\u003eEliminates need for a separate BMV battery monitor in GX-based systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax Current\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eVE.Can\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003eUp to 70V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTerminal Size\u003c\/td\u003e\n\u003ctd\u003eM10\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e170 x 186 x 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eLynx System Integration\u003c\/h3\u003e\n\u003cp\u003eThe Lynx product family uses a modular snap-together design — individual Lynx units connect side-by-side to form a clean, safe high-current DC distribution centre. Combine a Lynx Power In, Lynx Distributor, and Lynx Shunt to create a compact, professional battery management hub for your system.\u003c\/p\u003e\n\n\u003ch3\u003eUse Cases\u003c\/h3\u003e\n\u003cp\u003eIn off-grid solar systems paired with a Cerbo GX or Ekrano GX, the Lynx Shunt VE.Can replaces a standalone battery monitor and integrates battery data directly into the GX dashboard and VRM portal. Track battery state of charge, daily cycling history, and alarm thresholds remotely — essential for unattended off-grid cabins, pumping stations, and telecommunications sites.\u003c\/p\u003e\n\u003cp\u003eOn marine vessels and large motorhomes, the Lynx Shunt provides accurate battery monitoring across high-capacity lithium or lead-acid banks. The VE.Can connection to a Cerbo or Ekrano GX ensures battery state of charge is always visible on the onboard touchscreen and accessible remotely via VRM — critical for voyage planning and power management at anchor.\u003c\/p\u003e\n\n\u003ch3\u003eWhy Buy From Revolution Power\u003c\/h3\u003e\n\u003cp\u003eRevolution Power is a Queensland-based Victron Energy specialist. Fast shipping Australia-wide from Coomera, QLD. Contact us for advice on which Lynx combination suits your battery bank and load requirements.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":44837335040054,"sku":"LYN040102110","price":459.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/2989\/7782\/files\/Lynx_Shunt_1000A_top_LYN040102000_f9361403-0ccd-4a07-b8d0-760d9970df4a.webp?v=1771456232"}],"url":"https:\/\/revolution-power-australia.myshopify.com\/collections\/distribution-protection.oembed","provider":"Revolution Power Australia","version":"1.0","type":"link"}